Untitled Document Visit Our Ebay Store: THE BIGGEST ASSORTMENT of Gas Forges, Gas Burners, Metal Melting Furnaces INCLUDED GAS REGULATOR WITH USA CONNECTION (POL CGA-510) SHIPPING INFORMATIONDelivery time: 5-8 business days. The packages are shipped via FEDEX.(NOTE: delivery time is similar whether You buy from us from Europe – Lithuania, or from the United States) DFC Gas Burner for Gas Forges and Metal Melting Furnaces, Efficient and Economical DFC burner (180,000 BTU). Powerful and efficient. Our nozzle design is lasting longer and increases the burner’s efficiency. Burner’s Nozzle is made of 304 Stainless steel (burner’s nozzle at the widest place is 5cm). Its operating pressure range 1 – 25 PSI. There is a choke on the top of our burner – it regulates the amount of air that is mixed with the propane during combustion. Note: If You are looking for a good burner, You must know one thing – good burner must have air choke. If the burner doesn’t have it (don’t look at that side!), You can’t reach maximum temperature because you need a different quantity of air on different pressure! WATCH VIDEO “LESSON HOW TO REGULATE AIR CHOKE TO REACH IDEAL FLAME” Our burners are manufactured for work with: Butane Propane Butane + Propane Gas LPG Our burners don’t work on Natural Gas. Connection kit included: Gas pressure regulator, gauge with manometer; 6.5 ft (2m) gas hose; 2 clamps; All you need to supply is the propane tank. Our manometer with Mpa measurement. 0.1Mpa – 1Bar – 14.5PSI The manometer advantages: You can adjust exact gas pressure You need and control gas consumption. You can see when the pressure is falling down. Table explanation: ATM: Gas pressure from gas pressure regulator (in Atmospheres). 1ATM – 1.01Bar – 14.5PSI PSI: Gas pressure from gas pressure regulator (in Pounds per square inch). 1PSI – 0.06ATM – 0.068Bar BTU/Hr: British thermal unit per hour. 1 BTU/hr = 0.00029307107 kW LBS/Hr: Pounds per hour. 1 lbs = 0.45359237 kilograms Kg/Hr: Kilogram per hour. 1 kilogram = 2.20462262 lbs KW/Hr: Kilowatt per hour. 1 kW/Hr = 3412.142 BTU/Hr DFC PSI ATM BTU/H lbs/h KW/h Kg/h 1 0,07 36.674 1,70 10,75 0,77 2 0,14 51.864 2,40 15,20 1,09 3 0,20 63.520 2,94 18,62 1,33 4 0,27 73.347 3,40 21,50 1,54 5 0,34 82.005 3,80 24,03 1,72 6 0,41 89.832 4,16 26,33 1,89 7 0,48 97.029 4,49 28,44 2,04 8 0,54 103.728 4,80 30,40 2,18 9 0,61 110.021 5,10 32,24 2,31 10 0,68 115.972 5,37 33,99 2,44 15 1,02 142.036 6,58 41,63 2,98 20 1,36 164.009 7,60 48,07 3,45 25 1,70 183.368 8,49 53,74 3,85 30 2,04 200.869 9,30 58,87 4,22 35 2,38 216.964 10,05 63,59 4,56 40 2,72 231.944 10,74 67,98 4,87 Graphic explanation: BTU/Hr: burner power. PSI: gas pressure from gas pressure regulator. Other our Gas burners below: Illustrations may vary from actual product design, but the specifications are the same. User manual in English is included.
Archives
DF-AIR-FORCED GAS BURNER Propane Forge Furnace Foundry Blacksmith Farrier Knife
Visit Our eBay Store: THE BIGGEST ASSORTMENT of Gas Forges, Gas Burners, Metal Melting Furnaces SHIPPING INFORMATION Delivery time in European Union: 2-7 business days; USA, Canada: 5-8 business days; other countries: 5-12 business days. The packages are shipped via FEDEX, UPS, DPD, TNT, GLS, DHL. One of these gas pressure regulators included depending on the country: · Gas regulator with POL CGA-510 connection included for: UNITED STATES, CANADA, SWEDEN, NORWAY, AUSTRALIA, NEW ZEALAND, ISRAEL, MEXICO, INDONESIA, THAILAND · Gas regulator with G 5/8″UK POL LH connection included for: UNITED KINGDOM, SOUTH AFRICA · Our standard gas pressure regulator with connection – Shell DIN external thread to – W21.8 x 1/14″LH internal thread (Left thread) included for all other countries not mentioned above. (Fits to GERMANY, AUSTRIA, FRANCE, NETHERLANDS, SPAIN, BELGIUM, SLOVENIA, FINLAND, POLAND, LATVIA, RUSSIA and other countries)· Gas regulator with W20 x 1/14″LH connection included for: ITALY If you want a gas regulator other than mentioned for your country – let us know and we will adjust your order. DF AIR FORCED Gas Burner for Large Forges and Furnaces, Efficient and Economical DF AIR FORCED burner (308,000 BTU). Powerful and efficient. It is intended for large forges and furnaces. It reaches welding temperature in all large forges and melting temperature in large furnaces. It’s an excellent choice for professional use! Our nozzle design is lasting longer and increases the burner’s efficiency. Burner’s Nozzle is made of 304 Stainless steel (burner’s nozzle at the widest place is 5cm). Its operating pressure range 1 – 25 PSI. The forced air burner runs much hotter, heats faster, and allows you to adjust air to gas ratio for optimal heat and gas usage. The forced air burner is simple, it can be hooked up to any air compressor and by opening the ball valve adjusts the air to gas ratio creating a super hot flame. It also reduced fuel consumption and heating time. Air compressor requirements: – Need 2HP power, 24 liter receiver and 100 liter per minute compressor. Normal 0 false false false MicrosoftInternetExplorer4 Our burners are manufactured for work with: Butane Propane Butane + Propane Gas LPG Our burners don’t work on Natural Gas. Connection kit included: Gas pressure regulator, gauge with manometer; 6.5 ft (2m) gas hose; 2 clamps. All you need to supply is the propane tank and air compressor. Our manometer with Mpa measurement. 0.1Mpa – 1Bar – 14.5PSI The manometer advantages: You can adjust exact gas pressure You need and control gas consumption. You can see when the pressure is falling down. Table explanation: ATM: Gas pressure from gas pressure regulator (in Atmospheres). 1ATM – 1.01Bar – 14.5PSI PSI: Gas pressure from gas pressure regulator (in Pounds per square inch). 1PSI – 0.06ATM – 0.068Bar BTU/Hr: British thermal unit per hour. 1 BTU/hr = 0.00029307107 kW LBS/Hr: Pounds per hour. 1 lbs = 0.45359237 kilograms Kg/Hr: Kilogram per hour. 1 kilogram = 2.20462262 lbs KW/Hr: Kilowatt per hour. 1 kW/Hr = 3412.142 BTU/Hr DF (air forced) PSI ATM BTU/H lbs/h KW/h Kg/h 1 0,07 61.577 2,85 18,04632 1,29 2 0,14 87.083 4,03 25,52136 1,83 3 0,20 106.654 4,94 31,25715 2,24 4 0,27 123.154 5,70 36,09265 2,59 5 0,34 137.690 6,38 40,35281 2,89 6 0,41 129.284 5,99 37,88939 2,72 7 0,48 162.917 7,55 47,74609 3,42 8 0,54 174.166 8,07 51,04271 3,66 9 0,61 184.731 8,56 54,13897 3,88 10 0,68 194.723 9,02 57,06749 4,09 15 1,02 238.486 11,05 69,89311 5,01 20 1,36 275.380 12,75 80,70562 5,79 25 1,70 307.884 14,26 90,23162 6,47 30 2,04 337.270 15,62 98,84379 7,09 35 2,38 364.293 16,87 106,7635 7,65 40 2,72 389.446 18,04 114,135 8,18 Graphic explanation: BTU/Hr: burner power. PSI: gas pressure from gas pressure regulator. Untitled Document
DF-AIR-FORCED GAS BURNER Propane Forge Furnace Foundry Blacksmith Farrier USA
Visit Our eBay Store: THE BIGGEST ASSORTMENT of Gas Forges, Gas Burners, Metal Melting Furnaces INCLUDED GAS REGULATOR WITH USA CONNECTION (POL CGA-510) SHIPPING INFORMATIONDelivery time: 5-8 business days. The packages are shipped via FEDEX.(NOTE: delivery time is similar whether You buy from us from Europe – Lithuania, or from the United States) DF AIR FORCED Gas Burner for Large Forges and Furnaces, Efficient and Economical DF AIR FORCED burner (308,000 BTU). Powerful and efficient. It is intended for large forges and furnaces. It reaches welding temperature in all large forges and melting temperature in large furnaces. It’s an excellent choice for professional use! Our nozzle design is lasting longer and increases the burner’s efficiency. Burner’s Nozzle is made of 304 Stainless steel (burner’s nozzle at the widest place is 5cm). Its operating pressure range 1 – 25 PSI. The forced air burner runs much hotter, heats faster, and allows you to adjust air to gas ratio for optimal heat and gas usage. The forced air burner is simple, it can be hooked up to any air compressor and by opening the ball valve adjusts the air to gas ratio creating a super hot flame. It also reduced fuel consumption and heating time. Air compressor requirements: – Need 2HP power, 24 liter receiver and 100 liter per minute compressor. Normal 0 false false false MicrosoftInternetExplorer4 Our burners are manufactured for work with: Butane Propane Butane + Propane Gas LPG Our burners don’t work on Natural Gas. Connection kit included: Gas pressure regulator, gauge with manometer; 6.5 ft (2m) gas hose; 2 clamps. All you need to supply is the propane tank and air compressor. Our manometer with Mpa measurement. 0.1Mpa – 1Bar – 14.5PSI The manometer advantages: You can adjust exact gas pressure You need and control gas consumption. You can see when the pressure is falling down. Table explanation: ATM: Gas pressure from gas pressure regulator (in Atmospheres). 1ATM – 1.01Bar – 14.5PSI PSI: Gas pressure from gas pressure regulator (in Pounds per square inch). 1PSI – 0.06ATM – 0.068Bar BTU/Hr: British thermal unit per hour. 1 BTU/hr = 0.00029307107 kW LBS/Hr: Pounds per hour. 1 lbs = 0.45359237 kilograms Kg/Hr: Kilogram per hour. 1 kilogram = 2.20462262 lbs KW/Hr: Kilowatt per hour. 1 kW/Hr = 3412.142 BTU/Hr DF (air forced) PSI ATM BTU/H lbs/h KW/h Kg/h 1 0,07 61.577 2,85 18,04632 1,29 2 0,14 87.083 4,03 25,52136 1,83 3 0,20 106.654 4,94 31,25715 2,24 4 0,27 123.154 5,70 36,09265 2,59 5 0,34 137.690 6,38 40,35281 2,89 6 0,41 129.284 5,99 37,88939 2,72 7 0,48 162.917 7,55 47,74609 3,42 8 0,54 174.166 8,07 51,04271 3,66 9 0,61 184.731 8,56 54,13897 3,88 10 0,68 194.723 9,02 57,06749 4,09 15 1,02 238.486 11,05 69,89311 5,01 20 1,36 275.380 12,75 80,70562 5,79 25 1,70 307.884 14,26 90,23162 6,47 30 2,04 337.270 15,62 98,84379 7,09 35 2,38 364.293 16,87 106,7635 7,65 40 2,72 389.446 18,04 114,135 8,18 Graphic explanation: BTU/Hr: burner power. PSI: gas pressure from gas pressure regulator. Untitled Document